Evaluasi Overhaul terhadap Efisiensi Boiler Unit 3 PLTU Lontar
DOI:
https://doi.org/10.58466/vrfmq234Keywords:
boiler efficiency; overhaul; direct method; indirect method; heat lossAbstract
The boiler is the main component of a steam power plant because it converts feedwater into high-temperature and high-pressure steam for turbine operation. Boiler efficiency is affected by combustion quality, coal characteristics, air supply, heat-transfer cleanliness, and the condition of auxiliary equipment. This study evaluates the effect of overhaul on the efficiency of Boiler Unit 3 at UJP PLTU Banten 3 Lontar. The calculation uses performance-test data before and after overhaul at a 294 MW load. Two methods are applied: the direct or input-output method and the indirect or heat-loss method based on ASME PTC 4. The direct-method efficiency increased from 79.51% before overhaul to 79.68% after overhaul, equivalent to a 0.17 percentage-point improvement. The indirect-method efficiency increased from 81.85% to 82.61%, equivalent to a 0.76 percentage-point improvement. The reduction in dry flue-gas loss, hydrogen-moisture loss, coal-moisture loss, and air-moisture loss indicates that overhaul improves boiler heat utilization, especially through tube cleaning, air-preheater cleaning, and restoration of combustion-supporting equipment. The results confirm that scheduled overhaul can improve boiler performance and should be maintained as part of plant reliability management
Downloads
References
[1] E. Nugroho, Optimalisasi Kinerja Soot Blower pada Boiler PLTU Tanjung Jati B, Yogyakarta, 2013.
[2] Nurmalita, Analisis Efisiensi Energi pada PLTU PT Energi Alamraya Semesta, Bogor: Institut Pertanian Bogor, 2012.
[3] S. F. dan P. Ramadhan, Analisa Efisiensi Boiler dengan Metode Heat Loss Sebelum dan Sesudah Overhaul PT Indonesia Power UJP PLTU Lontar Unit 3, Jurnal Power Plant, 2017, pp. 218-227.
[4] M. F. Ramadhan, Analisis Nilai Excess Air terhadap Efisiensi Boiler pada PLTU Batubara Unit Pembangkitan Pelabuhan Ratu 3 x 350 MW, Jakarta: STT-PLN, 2018.
[5] PT PLN, Modul Training Boiler, Palabuhan Ratu, 2012.
[6] PT PLN, Modul Operasi Pembakaran, Palabuhan Ratu, 2013.
[7] Bureau of Energy Efficiency, Energy Performance Assessment of Boilers.
[8] ASME, Performance Test Code for Fired Steam Generators, ASME PTC 4, 2013.
[9] Putra TS, Prabowo E, Ramadani F. Pengaruh Overhaul Terhadap Kinerja High Pressure Heater Unit 3 PLTU Banten Lontar. JTM: JURNAL TEKNIK MESIN. 2026 Feb 1;2(1):10-5
[10] M. M. El-Wakil, Powerplant Technology, New York: McGraw-Hill, 1984.
[11] P. K. Nag, Power Plant Engineering, New Delhi: Tata McGraw-Hill, 2008.