Evaluasi Rasio Coal Blending terhadap Efisiensi Boiler Unit 7 Suralaya

Authors

  • Eri Prabowo Institut Teknologi Perusahaan Listrik Negara (ITPLN)
  • Trassanda Scudetto Widestomo Putra Institut Teknologi Perusahaan Listrik Negara (ITPLN)
  • Tegar Aris Prayoga Institut Teknologi Perusahaan Listrik Negara (ITPLN)

DOI:

https://doi.org/10.58466/8t6mxj35

Keywords:

boiler efficiency; coal blending; heat loss; calorific value; SFC

Abstract

This study evaluates the effect of coal blending ratio on boiler efficiency at Unit 7 of PT Indonesia Power Suralaya PGU. The analysis used low-rank coal (LRC) and medium-rank coal (MRC) with three blending ratios, namely 25L:75M, 50L:50M, and 75L:25M. Boiler performance was calculated using the indirect heat-loss method and compared with the direct input-output method. The main evaluated variables were coal quality, calorific value, moisture, ash, ultimate analysis, dry flue-gas loss, hydrogen-moisture loss, fuel-moisture loss, air-moisture loss, and specific fuel consumption. The results show that increasing the MRC fraction improves calorific value and tends to reduce moisture-related losses. The 25L:75M ratio consistently produced the best mixed-coal performance. In February 2020, the BB-2 mixture with 25L:75M achieved the highest indirect boiler efficiency of 85.798%, while the direct-method efficiency reached 73.845%. Therefore, the 25L:75M blending ratio is recommended as the most suitable operating option among the evaluated mixtures

Downloads

Download data is not yet available.

References

[1] Baek SH, Park HY, Ko SH. The effect of the coal blending method in a coal fired boiler on carbon in ash and NOx emission. Fuel. 2014;128:62-70.

[2] Liu G, Li Z, Chen Z, Zhu X, Zhu Q. Effect of the anthracite ratio of blended coals on combustion and NOx emission characteristics of a 660-MWe utility boiler. Appl Energy. 2012;95:196-201.

[3] Zheng S, Hu Y, Wang Z, Cheng X. Experimental investigation on ignition and burnout characteristics of semi-coke and bituminous coal blends. J Energy Inst. 2020;93(4):1373-1381.

[4] Samsudin S, Aziz NA, Sukhri MH. Sub bituminous coal blended analysis. 2020:739-748.

[5] M Raut S, Kumbhare SB, Thakur KC. Energy performance assessment of boiler at PSSK Ltd, Basmathnagar, Maharashtra State. Int J Emerg Technol Adv Eng. 2014;4(12):1-12.

[6] Nagar V. Boiler efficiency improvement through analysis of losses. Int J Sci Res Dev. 2013;1(3):1-5.

[7] Pravitasari Y, Malino MB, Novitasari M. Analisis efisiensi boiler menggunakan metode langsung. Prisma Fisika. 2017;5(1):9-12.

[8] Saputra D, Triantoro A. Kajian blending dua jenis grade batubara beda kualitas. 2013:40-55.

[9] Divo M. Optimasi pencampuran batubara beda kualitas dengan metode trial and error untuk memenuhi kriteria permintaan konsumen di CV Bara Mitra Kencana Kota Sawahlunto. 5(1):51-60.

[10] Putra TS, Prabowo E, Ramadani F. Pengaruh Overhaul Terhadap Kinerja High Pressure Heater Unit 3 PLTU Banten Lontar. JTM: JURNAL TEKNIK MESIN. 2026 Feb 1;2(1):10-5.

Published

2026-08-01

Issue

Section

Artikel

How to Cite

Evaluasi Rasio Coal Blending terhadap Efisiensi Boiler Unit 7 Suralaya. (2026). JTM : JURNAL TEKNIK MESIN, 2(2), 147-154. https://doi.org/10.58466/8t6mxj35

Similar Articles

1-10 of 23

You may also start an advanced similarity search for this article.