Evaluasi Rasio Coal Blending terhadap Efisiensi Boiler Unit 7 Suralaya

Penulis

  • Eri Prabowo Institut Teknologi Perusahaan Listrik Negara (ITPLN)
  • Trassanda Scudetto Widestomo Putra Institut Teknologi Perusahaan Listrik Negara (ITPLN)
  • Tegar Aris Prayoga Institut Teknologi Perusahaan Listrik Negara (ITPLN)

DOI:

https://doi.org/10.58466/8t6mxj35

Kata Kunci:

efisiensi boiler, coal blending, heat loss, nilai kalor, SFC

Abstrak

Penelitian ini mengevaluasi pengaruh rasio coal blending terhadap efisiensi boiler Unit 7 PT Indonesia Power Suralaya PGU. Analisis menggunakan batubara low-rank coal (LRC), medium-rank coal (MRC) dengan tiga rasio campuran yaitu 25 L: 75 M, 50 L:50 M, 75 L: 25 M. Kinerja boiler dihitung menggunakan metode tidak langsung berbasis heat loss dan dibandingkan dengan metode langsung input-output. Variabel utama yang dievaluasi meliputi kualitas batubara, nilai kalor, moisture, ash, analisis ultimat, kerugian gas, buang kering, kerugian akibat moisture hidrogen, moisture bahan bakar, moisture udara, dan specific fuel consumption. Hasil menunjukan bahwa peningkatan fraksi MRC memperbaiki nilai kalor dan cenderung menurunkan losses terkait moisture. Rasio 25L: 75 MM memberikan performa campuran paling konsisten. Pada Februari 2020, campuran BB-2 rasio 25L:75 M menghasilkan efisiensi boiler inderect tertinggi sebesar opsi operasi paling sesuai di antara campuran yang dievaluasi 

Unduhan

Data unduhan tidak tersedia.

Referensi

[1] Baek SH, Park HY, Ko SH. The effect of the coal blending method in a coal fired boiler on carbon in ash and NOx emission. Fuel. 2014;128:62-70.

[2] Liu G, Li Z, Chen Z, Zhu X, Zhu Q. Effect of the anthracite ratio of blended coals on combustion and NOx emission characteristics of a 660-MWe utility boiler. Appl Energy. 2012;95:196-201.

[3] Zheng S, Hu Y, Wang Z, Cheng X. Experimental investigation on ignition and burnout characteristics of semi-coke and bituminous coal blends. J Energy Inst. 2020;93(4):1373-1381.

[4] Samsudin S, Aziz NA, Sukhri MH. Sub bituminous coal blended analysis. 2020:739-748.

[5] M Raut S, Kumbhare SB, Thakur KC. Energy performance assessment of boiler at PSSK Ltd, Basmathnagar, Maharashtra State. Int J Emerg Technol Adv Eng. 2014;4(12):1-12.

[6] Nagar V. Boiler efficiency improvement through analysis of losses. Int J Sci Res Dev. 2013;1(3):1-5.

[7] Pravitasari Y, Malino MB, Novitasari M. Analisis efisiensi boiler menggunakan metode langsung. Prisma Fisika. 2017;5(1):9-12.

[8] Saputra D, Triantoro A. Kajian blending dua jenis grade batubara beda kualitas. 2013:40-55.

[9] Divo M. Optimasi pencampuran batubara beda kualitas dengan metode trial and error untuk memenuhi kriteria permintaan konsumen di CV Bara Mitra Kencana Kota Sawahlunto. 5(1):51-60.

[10] Putra TS, Prabowo E, Ramadani F. Pengaruh Overhaul Terhadap Kinerja High Pressure Heater Unit 3 PLTU Banten Lontar. JTM: JURNAL TEKNIK MESIN. 2026 Feb 1;2(1):10-5.

Unduhan

Diterbitkan

2026-08-01

Terbitan

Bagian

Artikel

Cara Mengutip

Evaluasi Rasio Coal Blending terhadap Efisiensi Boiler Unit 7 Suralaya. (2026). JTM : JURNAL TEKNIK MESIN, 2(2), 147-154. https://doi.org/10.58466/8t6mxj35

Artikel Serupa

1-10 dari 23

Anda juga bisa Mulai pencarian similarity tingkat lanjut untuk artikel ini.

Artikel paling banyak dibaca berdasarkan penulis yang sama

1 2 > >>