Evaluasi Operasi PLTD Kamanggih Pasca-Interkoneksi pada Sistem Waingapu
DOI:
https://doi.org/10.58466/21ca3t15Keywords:
interconnection; PLTD; SFC; SLC; BPPAbstract
This study evaluates the operational effect of connecting PLTD Kamanggih to the Waingapu system through a 20 kV interconnection network. The study used operational, production, fuel, lubricant, cost, and system-capacity data from January 2023 to June 2024. The main indicators were Specific Fuel Consumption (SFC), Specific Lubricant Consumption (SLC), and Cost of Electricity Production (BPP). Before interconnection, PLTD Kamanggih had higher SFC, SLC, and BPP than PLTD Waingapu, namely 0.41661 liter/kWh, 0.00401 liter/kWh, and 5,785.48 Rp/kWh, while PLTD Waingapu recorded 0.27945 liter/kWh, 0.00012 liter/kWh, and 3,160.71 Rp/kWh. After the interconnection, Kamanggih's 0.114 MW load was supplied by the Waingapu system, which still had sufficient available capacity. The best comparison occurred between the second quarter of 2023 and the second quarter of 2024, where SFC decreased by 0.00729 liter/kWh or 2.59%, SLC decreased by 0.00012 liter/kWh or 73.94%, and BPP decreased by 87.57 Rp/kWh or 2.63%. The result indicates that 20 kV interconnection is effective as a dedieselization strategy to improve operational efficiency, reduce isolated diesel operation, and lower electricity production cost.
Downloads
References
[1] Tasfif A. Rencana Usaha Penyediaan Tenaga Listrik PT PLN (Persero). Jakarta: Menteri Energi dan Sumber Daya Mineral Republik Indonesia; 2021.
[2] Prabowo MF. Optimasi Pengembangan Penyedia Daya Cadangan Hybrid di Daerah Muntok Pulau Bangka. Yogyakarta: Universitas Islam Indonesia; 2018.
[3] Masrianto, Rahman ES, Ruslan. Studi tentang proses pembangkitan listrik tenaga diesel PT PLN (Persero) Wilayah SULSELRABAR Sektor Tello Makassar. 2019:1-6.
[4] Wanevi SK, Arzul. Studi analisa Specific Fuel Consumption pada PT PLN (Persero) PLTD Bengkalis Riau. 2022:1-5.
[5] Susanto I, Sunanda W, Kurniawan R. Analisis pembangkit tenaga diesel di Pulau Celagen. 2019:2-4.
[6] Krismanto AI. Analisis Perencanaan Rekonfigurasi Kelistrikan Labuan Bajo untuk Mendukung Program Kawasan Strategis Pariwisata Nasional dengan Sistem Zero Down Time. 2022:8-12.
[7] Budi I, Wartana IM, Setiawan C. Analisa performa interkoneksi PLTS pada sistem kelistrikan 20 kV Lombok Nusa Tenggara Barat. Jurnal Fortech. 2023:1-9.
[8] Premadi A, Ilmi F. Analisa kualitas penyaluran daya pada sistem 20 kV Painan terhadap interkoneksi dengan PLTM Lumpo 3 MW. JTE-ITP. 2021:1-4.
[9] Hay S. Perhitungan Biaya Pokok Penyediaan tenaga listrik per golongan pelanggan studi kasus PT PLN (Persero) Sistem SULSELTRABAR. Dinamika Jurnal Ilmiah Teknik Mesin. 2014:2-4.
[10] Ruchiyat A. Pengaruh frekuensi sistem terhadap konsumsi bahan bakar pada beban puncak mesin Ruston 16 RKC. Jurnal Simetrik. 2020:1-6.
[11] J B, Camerling, Fretes RD. Pemilihan alternatif bahan bakar mesin pembangkit PLTD. Jurnal METIKS. 2021;1(1):1-5.
[12] Cappenberg AD. Pengaruh penggunaan bahan bakar solar, biosolar dan Pertamina Dex terhadap prestasi motor diesel silinder tunggal. Jurnal Konversi Energi dan Manufaktur UNJ. 2017;2:1-6.
[13] Hartono R, Saputra DA. Biodiesel B30 terhadap Specific Fuel Consumption mesin. Dinamika Jurnal Teknik Mesin UNKHAIR. 2022:1-4.
[14] Pasak ZR. Analisa Unjuk Kerja PLTD Berbahan Bakar Biodiesel (B30) pada ULPLTD Hative Kecil, Kota Ambon. Makassar: Politeknik Ujung Pandang; 2023.
[15] Tanjung A, Maulana Z, Yuvendius H. Analisis generator sinkron Unit 2 akibat overheating di Pembangkit Listrik Tenaga Gas MPP Balai Pungut. 2023:2-5.
[16] PT PLN (Persero) ULPL Waingapu. Data pengusahaan, produksi energi, konsumsi BBM, minyak pelumas, dan BPP Sistem Waingapu tahun 2023-2024. Waingapu: PLN; 2024.
[17] PT PLN (Persero) UP3 Sumba. Data sistem kelistrikan dan konfigurasi jaringan 20 kV Pulau Sumba. Sumba: PLN; 2024.
[18] PT PLN (Persero) UP2K Sumba. Data pembangunan jaringan interkoneksi 20 kV Kamanggih-Waingapu. Sumba: PLN; 2024.
[19] Kementerian Energi dan Sumber Daya Mineral. Keputusan Menteri ESDM Nomor 188.K/HK.02/MEM.L/2021 tentang RUPTL PT PLN (Persero) 2021-2030. Jakarta: KESDM; 2021.
[20] PT PLN (Persero). Statistik PLN 2023. Jakarta: PT PLN (Persero); 2024.
[21] Putra TS, Prabowo E, Ramadani F. Pengaruh Overhaul Terhadap Kinerja High Pressure Heater Unit 3 PLTU Banten Lontar. JTM: JURNAL TEKNIK MESIN. 2026 Feb 1;2(1):10-5.