ANALISIS SISTEM KENDALI DUA POSISI PADA SOLENOID VALVE UNTUK PRODUK BIOGAS CONTROL AND MONITORING (COMMON-BIGOT) FROM ANIMAL WASTE

Authors

  • Imam Arifin Institut Teknologi Sumatera
  • Syamsyarief Baqaruzi Institut Teknologi Sumatera
  • Reynaldo Zoro Institut Teknologi Sumatera
https://doi.org/10.58466/injection.v1i2.1385

Keywords:

HCSR-04 Distance Sensor, Response Time and Set point, Solenoid Valve, Two Position Control System, Biogas

Abstract

Biogas is gas produced by bacteria when organic matter undergoes a fermentation process under anaerobic conditions, and will produce methane gas which is temporarily stored in a container called a biogas bag. The biogas bag needs to be controlled to ensure the biogas bag remains safe. The control system is in the form of a two-position control because it has the advantage of being cheap and simple, besides that the solenoid valve as an actuator has a non-linear output property. To detect the capacity of the biogas bag, the HCSR-04 proximity sensor is used as feedback on the set point value that is set, which is 50 cm for the maximum set point and 30 cm for the minimum set point. The results obtained by the proximity sensor is able to read the distance with an accuracy of 5.8% and the On-Off control has a response of 0.25 seconds.

References

Tampubolon, A.P., Aditama, J.I. ”Laporan Energi Bersih Indonesia: Potensi, Kapasitas terpasang, dan Rencana Pembangunan pembangkit Listrik Energi Terbarukan 2019”Institute for Essential Services Reform (IESR), 2019.

Suyitno, "Teknologi Biogas”, Yoogyakarta: Graha Ilmu, 2010.

R.Rahmawan, "Sistem Kotrol Produk Gas Metana pada Digester Tipe Fixed Dome”, Universitas Brawijaya, Malang,2013.

Hidayat, D., Rahmatika, M., Syafei, N.M.. "Analisa Respon Pengontrolan ON-OFF Pada Kendali Umpan Balik Sistem Fisis Elektronik”, EKSAKA,Unpad ,2018.

Junaidi, “Project Sistem Kendali Elektronik Berbasis Arduino”, Anugrah Utama Raharja, Gedongmeneng Bandar Lampung, 2018.

Supriyanto, “Pengertian dan Prisip Kerja Solenoid Valve”. [online] available: http://blog.unnes.ac.id/antosupri/pengertian-dan-prinsip-kerja-solenoid-valve/

Naylamphemachatronics “Solenoid Valve”,datasheet.

Basri, I.Y. Irfan, D. “Komponen Elektronika’, Sukabina Press, Padang, 2009.

Indotara, “Jenis Gangguan Listrik” [online] available:https://indotara.co.id/jenis-gangguan-listrik&id=403.html.

Published

2024-05-08

How to Cite

Arifin, I., Baqaruzi, S., & Zoro, R. (2024). ANALISIS SISTEM KENDALI DUA POSISI PADA SOLENOID VALVE UNTUK PRODUK BIOGAS CONTROL AND MONITORING (COMMON-BIGOT) FROM ANIMAL WASTE. Injection: Indonesian Journal of Vocational Mechanical Engineering, 1(2), 47-57. https://doi.org/10.58466/injection.v1i2.1385

Issue

Section

Artikel